PTDR-100: Utilities & Consumables |
|
|
- LPG or Natural Gas: approximately 500 liters/hr during pre-heating (one hour) and approximately 1.5 liters (less than half a gallon) per hour during normal operations
- Electrical: maximum consumption 130 kW, 380-415 Volts, 3-Phase; during normal operations, the system consumes 40-75 kWe; of which, 20-50 kW is from the plasma torches, and 25 kW is for balance of plant systems
- Water: 12 liters (3 gallons) per minute
- Sodium Hydroxide: 0.65-1.35 kg/hr (1.5-3 lb/hr) depending on the waste composition
|
| |
|
 |
 |
 |
|
|
 |
|
 |
|